Skip to main content

Prerequisites and Installation Guide Flowcharts

The Prysm Application Appliance and Prysm Application Suite software are configured to default factory settings. Additional field configurations are necessary to reflect the integration and functional requirements for each customer. Before configuring the Application Appliance, review this section and gather all necessary materials.

Prerequisites

Field installation and support personnel must be familiar with the following applications and procedures:

  • Prysm Digital Workplace and touch sensor installation and operation
  • Microsoft Windows 8.1 and Windows 10 desktops, applications, directory structure, navigation, text editing through Notepad
  • Nvidia control panel for navigating display resolutions settings
  • Basic Prysm Application Suite end user functions
  • Salesforce access for viewing and editing the Application Appliance Installation Record
  • VLC, VNC, and Windows network configuration process
  • VC or Video Conferencing Integration
  • Third-Party Applications Integration
    • File Storage Provider Integration
    • Skype for Business™ (S4B) Integration
    • Identity Provider (IdP) Integration
    • Active Directory Integration
    • Google Drive Integration

Prysm Application Suite Required Network Ports

To establish the appropriate connections for Prysm Application Suite operation, the minimum requirements for ports are shown in the following tables.

Prysm Application Suite for Prysm Hosted Cloud Service Ports

Port IDDescription of UseNotes
443APISecure Connection (https)
80 and 8080Standard Web TrafficCloud Access
587Outbound EmailShare Email Feature
12201LoggingCloud Access
5999Device Sharing ServiceCloud Access

Prysm Application Suite for Customer Hosted Server (On-Premise) Ports

Port IDDescription of UseNotes
443APICustomer Hosted Cloud Server
4433AdminPrysm Web Admin (https)
80 and 8080Standard Web TrafficServer Access
587Outbound EmailShare Email Feature
5757LoggingCustomer Hosted Cloud Server